Arista Module Status (Service Check)
  • 10 Jan 2023
  • 1 Minute to read
  • Dark
    Light
  • PDF

Arista Module Status (Service Check)

  • Dark
    Light
  • PDF

Article Summary

Service Check Category: Systems Checks

Passive: No

Description: This check is used to alert if the status for a module in an Arista device returns a status of nonoperational. It uses the Entity MIB (1.3.6.1.2.1.47.1.1.1.1.2) to get a list of the module names and the Entity-sensor MIB (.1.3.6.1.2.1.99.1.1.1.5) to get the status of those modules. Returned codes of 1 (ok) and 2 (unknown) are considers an "OK" status and a returned code of 3 (nonoperational) is considered a "Critical" status.

Check-specific Fields:
(See Service Check for generic configuration parameters.)

  • DESCRIPTION
    (Required) This field specifies a name for this check. The name entered must be unique among service check names on the host it is added to (the name may used again only on a different host). It is used to identify this specific check from among other service checks added to the same host.

Was this article helpful?