HP iLO System HW Status (Service Check)
  • 10 Jan 2023
  • 1 Minute to read
  • Dark
    Light
  • PDF

HP iLO System HW Status (Service Check)

  • Dark
    Light
  • PDF

Article summary

Service Check Category: HP Insight Manager Agent Checks

Passive: No

Description: This service check monitors the hardware status of a an HP iLO module (with an option to specify the IP address of the iLO card instead of the address of the device configured).

The OIDs fetched from hp_system_mib are listed below:

  • Drive Array Spare Status: .1.3.6.1.4.1.232.3.2.4.1.1.3
  • Logical Drive Status: .1.3.6.1.4.1.232.3.2.3.1.1.4
  • Physical Drive Status: .1.3.6.1.4.1.232.3.2.5.1.1.6
  • Temperature: .1.3.6.1.4.1.232.6.2.6.3.0
  • System Fan: .1.3.6.1.4.1.232.6.2.6.4.0
  • CPU Fan: .1.3.6.1.4.1.232.6.2.6.5.0
  • Power Supply State: .1.3.6.1.4.1.232.6.2.9.3.1.5
  • Memory Module State: .1.3.6.1.4.1.232.6.2.14.11.1.5
  • Power Supply Redundancy: 1.3.6.1.4.1.232.6.2.9.3.1.9
  • Physical Drive Condition: .1.3.6.1.4.1.232.3.2.5.1.1.37
  • Power supply Condition: 1.3.6.1.4.1.232.6.2.9.1.0
  • Fan Condition: 1.3.6.1.4.1.232.6.2.6.7.1.9
  • Memory Condition: 1.3.6.1.4.1.232.6.2.14.4

Check-specific Fields:
(See the entry Service Check for details on basic configuration options.)

  • DESCRIPTION
    (Required) This field specifies a name for this check. The name entered must be unique among service check names on the host it is added to (the name may used again only on a different host). It is used to identify this specific check from among other service checks added to the same host.
  • ILO IP Address
    (Optional) Specifies the IP address of the iLO card instead of the address of the device configured.

Was this article helpful?