Service Check Category: HP Insight Manager Agent Checks
Passive: No
Description
This service check monitors the hardware status of the various components of an HP iLO module (with an option to specify the IP address of the iLO card, rather than just using the address of the managed device containing the card to perform polling).
The return codes have different meanings for each component of a module. The following tables show how the return codes for each component map to their respective HP status and Netreo service check status.
Drive Array Spare Status
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
invalid
Warning
3
failed
Critical
4
inactive
OK
5
building
Critical
6
active
Critical
Logical Drive Status
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
failed
Unknown
4
unconfigured
OK
5
recovering
Warning
6
readyForRebuild
Warning
7
rebuilding
Warning
8
wrongDevice
Critical
9
badConnect
Critical
10
overheating
Critical
11
shutdown
Critical
12
expanding
Warning
13
notAvailable
Critical
14
queuedForExpansion
OK
15
multipathAccessDegraded
Warning
16
erasing
Warning
17
predictiveSpareRebuildReady
OK
18
rapidParityInitInProgress
Warning
19
rapidParityInitPending
Warning
20
noAccessEncryptedNoCntlrKey
Unknown
21
unencryptedToEncryptedInProgress
OK
22
newLogDrvKeyRekeyInProgress
OK
23
noAccessEncryptedCntlrEncryptnNotEnbld
Unknown
24
unencryptedToEncryptedNotStarted
OK
25
newLogDrvKeyRekeyRequestReceived
OK
Physical Drive Status
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
failed
Critical
4
predictiveFailure
Critical
5
erasing
OK
6
eraseDone
OK
7
eraseQueued
OK
8
ssdWearOut
Warning
9
notAuthenticated
Warning
Temperature
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
4
failed
Critical
System Fan
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
4
failed
Critical
CPU Fan
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
failed
Critical
Power Supply State
Code
HP Status
Netreo Status
0
unknown
Unknown
1
noError
OK
2
generalFailure
Critical
3
bistFailure
Critical
4
fanFailure
Critical
5
tempFailure
Critical
6
interlockOpen
Critical
7
epromFailed
Warning
8
vrefFailed
Critical
9
dacFailed
Critical
10
ramTestFailed
Critical
11
voltageChannelFailed
Critical
12
orringdiodeFailed
Critical
13
brownOut
Critical
14
giveupOnStartup
Warning
15
nvramInvalid
Critical
16
calibrationTableInvalid
Critical
Memory Module State
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Critical
Power Supply Redundancy
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
notRedundant
Critical
3
redundant
OK
Physical Drive Condition
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
4
failed
Critical
Power Supply Condition
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
4
failed
Critical
Fan Condition
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
4
failed
Critical
Memory Condition
Code
HP Status
Netreo Status
0
unknown
Unknown
1
other
OK
2
ok
OK
3
degraded
Warning
The OIDs fetched from hp_system_mib for each component are listed below: